{"id":1164,"date":"2016-04-12T15:55:14","date_gmt":"2016-04-12T15:55:14","guid":{"rendered":"http:\/\/www.mashruba.com\/?page_id=1164"},"modified":"2016-04-12T15:55:14","modified_gmt":"2016-04-12T15:55:14","slug":"digix-u","status":"publish","type":"page","link":"https:\/\/molecularhscl.com\/?page_id=1164","title":{"rendered":"Digital Radiography System Digix-CSA \/ Digix-CSA Adv"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone  wp-image-5470\" src=\"http:\/\/molecularhscl.com\/wp-content\/uploads\/2024\/05\/digix-csa-adv-csa-csm-cs-300x300.jpg\" alt=\"\" width=\"507\" height=\"507\" srcset=\"https:\/\/molecularhscl.com\/wp-content\/uploads\/2024\/05\/digix-csa-adv-csa-csm-cs-300x300.jpg 300w, https:\/\/molecularhscl.com\/wp-content\/uploads\/2024\/05\/digix-csa-adv-csa-csm-cs-1024x1024.jpg 1024w, https:\/\/molecularhscl.com\/wp-content\/uploads\/2024\/05\/digix-csa-adv-csa-csm-cs-150x150.jpg 150w, https:\/\/molecularhscl.com\/wp-content\/uploads\/2024\/05\/digix-csa-adv-csa-csm-cs-768x768.jpg 768w, https:\/\/molecularhscl.com\/wp-content\/uploads\/2024\/05\/digix-csa-adv-csa-csm-cs-45x45.jpg 45w, https:\/\/molecularhscl.com\/wp-content\/uploads\/2024\/05\/digix-csa-adv-csa-csm-cs.jpg 1400w\" sizes=\"(max-width: 507px) 100vw, 507px\" \/><\/p>\n<div class=\"product-short-des\">\n<p><strong>Product:<\/strong>\u00a0Digital Radiography (Ceiling Suspended)<\/p>\n<p><strong>Models:<\/strong>\u00a0MARS 15 &#8211; 80<\/p>\n<p><strong>Rating:<\/strong>\u00a015\/30\/40\/50\/50+\/65\/80 KW (250 &#8211; 1000 mA)<\/p>\n<p><strong>Series:<\/strong>\u00a0Digix-CSA \/ Digix-CSA Adv<\/p>\n<\/div>\n<div class=\"product_sb\">\n<div>Allengers Digix series of Digital Radiography Systems (Ceiling Suspended system with Auto Tracking \/ Auto Positioning feature) are specialized models for general and specialized radiography applications. These systems are available with single detector \/ dual detector options as per user intended applications.<\/div>\n<h3>Special Features:<\/h3>\n<ul>\n<li>\u201cIntegra X\u201d Integrated control panel for exposure and image parameters control.<\/li>\n<li><\/li>\n<li>Fully motorized 3D ceiling suspended stand with auto-tracking facility of tube with table &amp; vertical Bucky.<\/li>\n<li>Unlimited positioning freedom.<\/li>\n<li>Auto Positioning of system tube &amp; detector as per APR view (Optional)<\/li>\n<li>AEC Mode for table &amp; VBS (Optional)<\/li>\n<li>Image Preview is available in less than 3 seconds (no long wait for patients).<\/li>\n<li>Digital touch display on tube stand for various parameters &amp; selection. (Available in DigiX CSA ADV Only)<\/li>\n<li>DAP reading dose Display on software screen (Optional).<\/li>\n<li>Superb image quality due to fine pixels and high contrast range.<\/li>\n<li>Post-processing feature adds more to the image quality.<\/li>\n<li>High-resolution 3K x 3K detector. (Detector specific)<\/li>\n<li>DICOM 3.0 Compatible.<\/li>\n<li>Efficient and user-friendly workflow due to DICOM based system.<\/li>\n<li>Easy to connect with existing HIS \/ HMS \/ RIS \/ PACS in a hospital environment.<\/li>\n<li>Automatic Collimation as per Apr view (Optional).<\/li>\n<li>Oblique tracking of tube head synchronized with FPD in VBS (optional).<\/li>\n<li>Auto Image stitching in Table &amp; in VBS (Optional).<\/li>\n<li>Reporting Workstation (Optional).<\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Product:\u00a0Digital Radiography (Ceiling Suspended) Models:\u00a0MARS 15 &#8211; 80 Rating:\u00a015\/30\/40\/50\/50+\/65\/80 KW (250 &#8211; 1000 mA) Series:\u00a0Digix-CSA \/ Digix-CSA Adv Allengers Digix series of Digital Radiography Systems (Ceiling Suspended system with Auto Tracking \/ Auto Positioning feature) are specialized models for general and specialized radiography applications. These systems are available with single detector \/ dual detector options as per user intended applications. &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-1164","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/molecularhscl.com\/index.php?rest_route=\/wp\/v2\/pages\/1164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/molecularhscl.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/molecularhscl.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/molecularhscl.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/molecularhscl.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1164"}],"version-history":[{"count":0,"href":"https:\/\/molecularhscl.com\/index.php?rest_route=\/wp\/v2\/pages\/1164\/revisions"}],"wp:attachment":[{"href":"https:\/\/molecularhscl.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}